7L Electric portable ultra low volume sprayer disinfector sprayer

Item No.: 86
The machine has wide applied fields and can be used for sanitation and epidemic prevention in hospital, restaurant, hotel, and other public
areas. It is an ideal electric disinfecting machine with reliable performance and convenient use.
INQUIRY
List price: $59-79
Description
1. Brief Introduction
Our ultra-low capacity nebulizer can be widely used in disinfection, sterilization, insecticidal, formaldehyde removal and other spraying work. This product has many advantages such as accurate orientation, long range, good insecticidal effect, saving water and pesticide, spraying large fog drops on the back of leaves and safe for operator. In addition, it only needs a little pesticide in air and dust disinfection, moreover, the fog drop is small in diameter but large in quantity and it is well distributed and could float in the air a long time, which make the air and dust are disinfected effectively. So the nebulizer is well-liked by users.

This product is used in sanitation and epidemic prevention, disinfection, insecticidal, sterilization, humidification, etc. It is widely used in airports, animal farms, hotels, restaurants, aquatic markets, public transport vehicles, communities, hospitals, hotels, hotels, shopping malls, restaurants, outdoor parks, schools, cinemas, amusement parks, cars, trains, ferries, airplanes, workshops, greenhouses, etc.
2. Main Technical Parameters
Rated voltage  220V /110V
Power: 850W
Spray volume: 470ml/min
Droplet size: 15-50μm
Tank capacity: (5L) 7L
Power cord length: 5m
Hose length: 75cm
Net weight: 3.5kg
Carton size: 49*23*29CM
3. Precautions
①. This machine is not allowed to spray or fill with flammable, explosive, and corrosive substances such as alcohol, gasoline, benzene,
and high-concentration disinfectant (the disinfectant chemical must be diluted before use).
②. Please do not use the machine in CLOSED room. After the spray is finished, close the doors and windows to increase the application
effect and ensure the safety and health of the person applying it.
③. It is forbidden to clean the machine by liquids such as Banana oil or gasoline. When cleaning the appearance of the machine with
water or other neutral detergent, care should be taken not to allow water or neutral detergent to flow into the motor casing.
④. After each use, the unused liquid must be poured out, and the liquid should not pollute the environment. It is very important and
necessary to add water to the chemical tank and start praying for about 0.5 – 1 minutes to clean the machine pipeline to avoid the
corrosion of the machine and increase the service life of the machine.
⑤. It is forbidden to be placed in a high temperature environment or under the sun for a long time to prevent the machine from being
deformed, fade, or crack.
⑥. Do not unplug the plug by pulling the power cord.
 
4. If the machine has the following faults, you can do the preliminary check to eliminate the issue.
①. First, the motor doesn’t turn on: Check if the machine’s power switch is in
  (ON) mode.  Then, check to see if the plug is securely inserted or if the socket is loose or damaged. Lastly, check if the power is normal.
②. Second, the amount of fog is reduced or weakened: Check if the internal pipeline of the machine is folded, twisted, blocked, or cleaning.
 
5. Cleaning
①. Spray the machine with clean water 1-2 minutes.
②. Clean the tank with water after use.